Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)

INCINERATOR DESCRIPTION

The Model is for up to 300kgs capacity per batch load and will burn at around 55kgs per hour.  The unit has top loading design and has a heavy duty refractory cement lining for maximum heat retention. Unit have large top lid for easy loading, and specially designed front ash door, for ash removal. This unit operates at over 1100°C in the primary chamber to ensure complete combustion. This model also benefits from a heavy duty secondary chamber and burner which ensures a complete re-burn of any smoke and emissions and a 0.5 second gas retention time. PRIMARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation Large full size top load door and liquid retention sill 1 x diesel oil fired ignition burners operated on/off SECONDARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation 1 x diesel oil fired ignition burners operated on/off CHIMNEY Heavy-duty stainless steel casing 1.5m length 0.6m refractory lined stack CONTROL PANEL Control of 1 burner Timer control 0- 12 hours Integral fan timer control Temperature Monitoring Thermostatic Control Automatic Control Cycle time set up ANCILLARIES Operating and maintenance manuals Spares list CONTAINERISATION incinerator fully installed inside of 10 ft ISO certified container 3,5 kwA electricity generator, 1000 litres fuel tank Incinerator mounted on the silenblock cushion.

multiple diesel fuel combustion chambers Incinerator

*External diameter at base 6ft 1.8m *External diameter at top 4 1/2ft 1.35m *Internal diameter at base 3ft 0.9m *Internal diameter at top 3ft 0.9m *Thickness of wall at base 18cm *Thickness of wall at top 9cm *Perpendicular height of wall 4ft *Height of Iron bars from grate above ground 1ft Material Required *Puddle swish *5 or 6 Iron bars about 4 1/2ft 1.35m long each *Quantity of large stones for foundation  *2 empty kerosene tins for making vent holes *2ltrs of coal tar *2 brushes *Foundation 1ft-1 1/2ft deep is dug *Filled with large stones and puddle swish to ground level  *Empty kero tins are next placed into position where the vent holes are to appear *Wall 1ft high is built with puddle swish *Iron bars are put in position leaving a space of about 2cm-3cm between the bars 4ft 1.2m to be reached *Wall plastered smooth  multiple diesel fuel combustion chambers Performance capacity 120kg/hr GRE 1.25 for HCRW 96kg/hr GRE 1.25 for general waste. 40kg/hr GRE 3.00 for plastic Waste type: health care risk waste and general waste Chimney stack Chimney: 3.5mm mild steel Height from base: 11m and if there are buildings within 30m of the incinerator, chimney must extend at least 3m above the apexes of all the roofs of such buildings Diameter of chimney at top: 430mm Weight of stack: ± 500kg case and stack be painted with 400 °C heat resistant black paint Burners 1st chamber 850 oC -900oC 2nd chamber 1000oC Variable speed combustion air blowers Primary chamber volume ±1.05 cubic metres Mixing chamber volume ±0.30 cubic meters Settling chamber volume ±0.89 cubic meters Weight excluding chimney ±6 400kg at manufacture Firing tools supplied: Hoe, poker and rake Dimensions Length ±2 125mm Width ±1 890mm Height  ±2 125mm Extra width for burners ±1 000mm Loading door opening 610mm×540mm Hearth area ±1.19 square metres Description of grate/hearth: A full hearth to be supplied to prevent contaminated  liquids  from  flowing  into  ash  pit  without  being…
Read more

Incinerator 300 kg/hr Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day)

 Incinerator  300 kg/hr  Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph)   Incinerator  450 kg/hr  Burn Capacity (min. 1800 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph)   Incinerator main unit main body (primary chamber, secondary chamber, mix-combustion chamber   Filter Chamber   Chimney   PLC Panel   Oil Tank   Combustion burner   Wind Tube   Oil Tube   Filter brick   Ash clean tool   Blower   Furnace gate   One bag chamber maintenance material  Feed Capacity 600-1200 kg per feed Burning Rate Min. 300 kgs per hour Burning Time per Feed 2-4 hours Voltage 380V Power 1.48Kw Frequency 50Hz Fuel Natural Gas or Diesel Oil Fuel Mode Manual Fuel Consumption (Oil) Max 40 kgs per hour Fuel Consumption (Gas) Max 44 m3 per hour Waste Combustion Chamber 2400 liters Post Combustion Chamber 1200 liters Oil Tank Capacity 500 liters Chimney 10.0 M Chamber Material Firebrick, Refractory Concrete Max. Heat Value 340,000 Kcal per hour Operation Technical Specification Solid Chamber Temperature 800 Deg. C – 1000 deg. C Gas Chamber Temperature 1000 Deg. C – 1200 deg. C Chamber Anti-Rate 1450 Deg. C Residency Time…
Read more

waste incinerator overview

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 600kgs/Hr., up to 10ton per day.  Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. Key Features: * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime.  * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock.

INCINERATOR QUESTIONNAIRE

1. Type of waste: Trash   2. Any other type: 3. Quantity of waste generated per day in kg: (50 Ton per day) SOW 4. Duration – incinerator will be used per day: (Minimum 12 hours) SOW 5. Approximate moisture content:  6. Local incinerator operating and emission standards: US-EPA  7. What is the height of the chimney required: Not known 8. Fuel proposed to be used: Deiseal Oil  9. Availability of power and type: 220 or 110  10. Details of space available: Plenty of space  11. Do you require an automatic loading system: [**] Yes  [**] No  12. Do you require a gas scrubbing system: [**] Yes  [ ] No  13. How soon do you require the system to be delivered: 30  14. Any other specific requirements: 15. Nature: (Solid/Semi-solid/Liquid) Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system Imputing door Mouth Width (mm): 760*760 (approx.) Chimney External Diameter (mm): 300 ± 10 Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max) Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz 

Medical waste incinerators bio Capacity incinerator medical waste to high combustion temperature

Medical waste incinerator bio Capacity incinerator medical waste to high combustion temperature  With a smokeless device to protect the environment and with two combustion chambers equipped with gas burners or oil  -incinerator to burn large volume pieces of 70 cm  deviation: Automatic Control System  -destructive capacity from 20 to 30 kgs  First-room / Temperature = 900 ° C combustion  2nd bedroom / Temperature = 1200 ° c afterburner  -burner = 116Kw Burning Rate: 50Kg/Hr Feed Capacity: 150Kgs  Primary Combustion Chamber: 900 Litres Secondary Combustion Chamber: 300 Litres Mix Combustion Chamber: Yes Smoke Filter Chamber: Yes Feed Mode: Manual Power: 0.7kW Fuel Type: Diesel/LPG/Natural Gas Internal Dimension: 120 x 90 x 85cm (Primary Chamber) External Dimensions: 200 x 160 x 310cm (Without Chimney) Burning Efficiency: >98%

Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners At least 3000mm Loading door opening Minimum 700mm x 600mm Hearth area 5.00square meters Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated Primary chamber volume At least 3 cubic meters Mixing chamber volume At least 1 cubic meters Settling chamber volume At least 3 cubic meters Weight excluding chimney 15, 000kg at manufacture Firing tools supplied Hoe, Poker and rake

diesel Fuel incinerators

diesel Fuel incinerators 16.  The supplier must provide necessary information for the best of the installation.  This incinerator with “PYROLYTIC”  combustion must have: 17.  A combustion chamber of waste:   Perfectly tight door for the manual loading of waste.  The loading should be manual, batch load.   A burner of lighting which the use is limited to the ignition of waste.   Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out  of refractory.   The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and  insulates bricks in order to assure a minimum temperature on the outside sheet metal.   Composition of the refractory;   Refractory concrete:     Thickness :>100mm     Nature: 42% of Al203   Insulate in fibrous panels:     Thickness: >75mm   Nature: Calcium silicate.   Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of  electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 18.  A chamber of post combustion of gases   A burner of combustion of gases,   A device of injection of air allowing a total re-combustion of gases,   A device of air inlet of cooling of waste gases,   A sheath of evacuation of the gases burnt,   Carcass in strong sheet steel with support of connection   Composition of the refractory;   Refractory concrete:     Thickness :>150mm     Nature: 65%% of Al203   Insulate in fibrous panels:     Thickness: >85mm     Nature: Calcium   Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition,  permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   A secondary injection of air to ensure perfect oxygen content.

Hot Medical Waste Disposing Machine Burn rate per hour: 250 -300kg/hr

Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant.    Type Pyrolytic:- Hot Medical Waste Disposing Machine   Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator /Primary Combustion Chamber Type: continuous loading Capacity/Burn rate per hour: 250 -300kg/hr Temperature:  900-1200 oC   Material: External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or…
Read more

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR Incinerator type: Animal waste incinerator Load Capacity minimum:  1500 kg Burner fuel type:  Diesel Burner fuel rate max.:   20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. 1100 0C Afterburner chamber burning temperature min.  1300 0C Power supply 220V Incinerator items and electrical appliances should be weather proof and humidity resistant within the range of 30-90 % Incinerator should be compliant to the environmental protection rules in accordance to national legislation Maximum dimensions C Length C 5m, width C 3.5m, height C 5m INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification.  1.1 General description   The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit’s effective destruction of the combustion products.   For the Supply, installation & commissioning of a Medical Waste Incinerator as detailed below: i. Waste type Health care waste   ii. Waste density 125 to 350Kg/M3   iii.. Waste Calorific Value 4000 KCAL/Kg   iv. Moisture content 10-25%   v.  Estimated ash  residue 5-10%   vi.  Nominal capacity  50Kg/hour batch load   vii.  Secondary chamber 2 seconds @ 850°C   viii. Environmental NEMA ACT (EMCA) 1999, Waste management regulations, 2006 …
Read more