Biomedical Waste Any kind of strong or liquid waste which may offer a hazard of infection to people consisting of non-liquid tissue, body parts, blood or blood items and body fluids, research laboratory and also veterinary waste which includes human disease- triggering agents, and discarded sharps (i.e. syringes, needles, scalpel blades). Base Ash The program…
Read more
Burning Capability: 125 kg minimum/time (3-6times/ day), dual chamber, dual combustion system Imputing door Mouth Width (mm): 760 * 760 (approx.). Smokeshaft External Size (mm): 300 ± 10. Combustion Improver Device: 0.11 kw, Fuel intake: 7kg/ hr (max). Re-Burning Tool: Oil consumption: 5kg/h, 0.37 kw, Oil consumption: 10-20kg/ h. Voltage: 380v/220v Air Conditioner, Service Warranty:…
Read more
Including:Incinerator: Structure to be specified The mark to be specified Water temperature: 800 to 1000 ° C; Refractory Temperature of more than 1100 ° C + obtained; Capacity: 20-50 kg / hour Fireplace: 4 to 6 meters high; Dimension 70 cmx70 crn Height: 1.10 meters Fuel: coal; Aspiration: natural – A receiving cage for biomedical…
Read more
Incinerator double chamber with ability 1.5 m3/batch or 6 m3/ day, electronic thermocontrol range 0‐1200 C, thermocouple, air supply capacity 10m3/ minute, power usage 1.2 kWH/ hour, power 3 stage with netral, cooling water sprinkler capacity 5L/ minute, finished with refractory (insulation, castable, ceramic covering) and PLC SUPPLY, INSTALLATION As Well As COMMISSIONING OF WASTE…
Read more
Up to 600kgs per ten-hour day of Kind IV pathological waste or red bag waste rated at 2200 BTU’s per kg, based on batch packing twice daily. Burner, 20 kg/hr Burn Ability (min. 1200 kgs. Waste Feed Ability each day) (4-6 hrs procedures) (Power Supply 380V, 50Hz, 3Ph). Capacity: 30 kg/hr. Number product: 01 system…
Read more
SECTION V TECHNICAL SPECIFICATIONS OF THE INCINERATOR General Description The plant have to have four distinct sections that show three principles of disturbance, home time and temperature retention. The regulated areas may consist of but not limited to: Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum capacity of…
Read more
Functional Capacities PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING SYSTEM AUTOMATED ASH REMOVAL SYSTEM GAS…
Read more
health center waste administration group at a tertiary care health center,1250 beeded hsopital. our everyday waste created from all resources is 0.55 kg/bed/day =685kg/day we need an incinerator of 150kg/hour filling capability. plz reply with, buying, installment, running as well as upkeep cost.incinerators, especially, medical was burners Department of Health has actually floated a tender…
Read more
Air emission requirements establish limits on the quantity of contaminants that can be launched into the ambience. These standards are revealed as a focus in the exhaust gases leaving the stack as well as can being accomplished making use of usually available incineration innovation and waste diversion methods. The complying with emission standards1 relate to…
Read more
Polaris Power saving Information: With the substantial use the health care industry and also the advancement of clinical non reusable products, clinical waste generation is growing rapidly. The latest data reveal that there were 261, in the city to the neighborhood strong waste air pollution prevention details, just these 261 cities this year, medical waste…